menu

This product is a analog input which can be coupled to the ToolScope via EtherCAT. You need a bus coupler E65 19010 for that.

Short description of the delivered product (Quotation text)

  • None

Additional information to the delivered product

  • ToolScope of revision 3 can be connected with analog or digital outputs or inputs as they are needed.


     
  • The connection is done by an Ethernet cable via the EtherCAT protocol.
     
  • The ToolScope is connected to a EtherCAT bus coupler. It communicates with the coupler. The modular input and output units are added to the coupler.
     
  • BRINKHAUS delivers as standard unit
    • A module with 4 analog inputs (E65 19020 - the product which is described on this page)
    • A module with 4 analog outputs (E65 19030)
    • A module with 8 digital inputs (E65 19040)
    • A module with 8 digital outputs (E65 19050)
  • To supply the above mentioned modules with power and to connect them via EtherCAT to the ToolScope, one needs a bus coupler. This is  E65 19010.

 

  Task in the EtherCAT system Deliver analog input values
  Count of terminals 4 (differencial)
  Internal resistance > 200 kΩ
  Cycle delay 1µs
  Filter frequency of input filter 5 kHz
  Weight 65 g
  Power supply 24 V DC (-15 %/+20 %)
  Common-mode voltage UCM max. 35 V
  Sampling time ~ 100 µs
  Sampling resolution 16 Bit (incl. sign)
  Width in process image 16 bytes
  Error in measurement <0.3% of nominal range
  Electric isolation 500V (Power contact / Power supply / Ethernet)
  Current consumption E-Bus 130 mA typ.
  Certificates CE, UL, Ex
  Mechanic shock resistance EN 60068-2-6/EN 60068-2-27
  EMC resistance EN 61000-6-2/EN 61000-6-4
  Protection IP20
  Ambient temperature -25…+60 °C/-40…+85 °C (95% humidity, non condensating)
     

 