menu

This product is a bus coupler for adding analog and digital inputs and outputs to the ToolScope.

Short description of the delivered product (Quotation text)

  • Din rail device for the cabinet.

  • Module to connect additional digital/analog
    inputs/ouputs to a ToolScope.

Additional information to the delivered product

  • ToolScope of revision 3 can be connected with analog or digital outputs or inputs as they are needed.


     
  • The connection is done by an Ethernet cable via the EtherCAT protocol.
     
  • The ToolScope is connected to a EtherCAT bus coupler. It communicates with the coupler. The modular input and output units are added to the coupler.
     
  • BRINKHAUS delivers as standard unit
  • To supply the above mentioned modules with power and to connect them via EtherCAT to the ToolScope, one needs a bus coupler. This is  E65 19010 - the product described at this page.

 

  Task in the EtherCAT system Couple EtherCAT terminals to the EtherCAT network - the complete coupled module is later connected with EtherCAT to the ToolScope.
  Medium

Ethernet/EtherCAT-Cable (min. CAT 5), shielded

  Interface 2x RJ45
  Distance between stations max. 100 m (100BASE-TX)
  Count of EtherCAT terminals Up to

4x E65 19020 (Analog Inputs) >> 16 Signals
6x E65 19040 (Digital Inputs) >> 48 Signals
2x E65 19030 (Analog Outputs) >> 8 Signals
6x E65 19050 (Digital Outputs) >> 48 Signals
  Protocol EtherCAT
  Cycle delay 1µs
  Data rates 100 MBit
  Power supply 24 V DC (-15 %/+20 %)
  Current consumption E-Bus 2000 mA
  Current consumption 570mA
  Max current power contacts 10 A
  Electric isolation 500V (Power contact / Power supply / Ethernet)
  Certificates CE, UL, Ex
  Mechanic shock resistance EN 60068-2-6/EN 60068-2-27
  EMC resistance EN 61000-6-2/EN 61000-6-4
  Protection IP20
  Ambient temperature -25…+60 °C/-40…+85 °C (95% humidity, non condensating)
     
  • Other plugs and connectors may exist on the device but are not guaranteed to have a functionality.