The following is a guide through all outputs of the ToolScope standard FB 391. In our example project you find it used as example in an outer FB 390.

Collective_Alarm

Bool

Collective message for alarms on all monitoring channels

Collective_Breakage

Bool

Collective message for breakage alarms on all monitoring channels

Collective_Wear

Bool

Collective message for wear alarms on all monitoring channels

Collective_Missing

Bool

Collective message for missing alarms on all monitoring channels

Maximum_Alarm_Per_Ch

Array8 Bool

Channel-related message for maximum alarm

Breakage_Alarm_Per_Ch

Array8 Bool

Channel-related message for breakage alarm

Wear_Alarm_Per_Ch

Array8 Bool

Channel-related message for wear alarm

Missing_Alarm_Per_Ch

Array8 Bool

Channel-related message for missing alarm

Use_Counter_Alarm_Per_Ch

Array8 Bool

Channel-related message for batch counter

NCCH1_Rework_Active

Bool

Rework feedback activated

NCCH2_Rework_Active

Bool

Rework feedback activated

NCCH1_Breakage

Bool

Breakage alarm notification in this channel

NCCH2_Breakage

Bool

Breakage alarm notification in this channel

NCCH3_Breakage

Bool

Breakage alarm notification in this channel

NCCH4_Breakage

Bool

Breakage alarm notification in this channel

NCCH1_Wear

Bool

Wear alarm notification in this channel

NCCH2_Wear

Bool

Wear alarm notification in this channel

NCCH3_Wear

Bool

Wear alarm notification in this channel

NCCH4_Wear

Bool

Wear alarm notification in this channel

NCCH1_Missing

Bool

Missing alarm notification in this channel

NCCH2_Missing

Bool

Missing alarm notification in this channel

NCCH3_Missing

Bool

Missing alarm notification in this channel

NCCH4_Missing

Bool

Missing alarm notification in this channel

NCCH1_Ack_Alarm_False

Bool

"Alarm was not authorized" message

NCCH2_Ack_Alarm_False

Bool

"Alarm was not authorized" message

NCCH3_Ack_Alarm_False

Bool

"Alarm was not authorized" message

NCCH4_Ack_Alarm_False

Bool

"Alarm was not authorized" message

NCCH1_Ack_Alarm_Correct

Bool

"Alarm was authorized" message

NCCH2_Ack_Alarm_Correct

Bool

"Alarm was authorized" message

NCCH3_Ack_Alarm_Correct

Bool

"Alarm was authorized" message

NCCH4_Ack_Alarm_Correct

Bool

"Alarm was authorized" message

Message_Bus_Message_No

Byte

ToolScope message bus evaluation – Channel error code

Message_Bus_Glo_Msg_No

Byte

ToolScope message bus evaluation – Global error code

Message_Bus_Glo_Chan_No

Byte

ToolScope message bus evaluation – Monitoring channel no.

FB_Working

Bool

ToolScope module feedback will be processed without error

FB_Error_No

Int

Error number in the event of faulty parametrization

TS_Configuration_Error

Bool

ToolScope configuration error

TS_Working_And_Active

Bool

ToolScope ready

Remark on the "Ack_alarm_was_false_alarm" ("Quit_Alarm_war_Fehlalarm") and "Ack_alarm_was_correct" ("Quit_Alarm_war_korrekt") outputs: Internally, these work in the module as though the "Delete alarms" ("Alarme loeschen") input were active. Consequently: If a user acknowledges an alarm on the control panel, all alarm outputs are set to OFF.